6-9SectionSystem Settings
185
6-9-12 Setting the Time-out Interval
The NT31/NT31C goes into the time-out error status if no response is received
from the host within a fixed time. The Time-out Interval setting specifies the time
lapse at which time-out is judged to have occurred.
The setting range is 1 to 10 seconds. The default (factory) setting is 1 second.
Reference: Whether or not an error screen is displayed when a time-out error occurs is deter-
mined by the setting for the Comm. Auto-return memory switch.
Set the time-out interval by following the menu operation from the System Menu
shown below.
Select Maintenance Mode.
Select Memory Switch.
Press [] (next screen) or [] (previous
screen) to display the third memory switch
setting screen.
Press Time-out Interval to display the re-
quired time lapse.
The setting option changes each time the
touch switch is pressed, according to the fol-
lowing sequence.
01 02 03 .... 09 10 01 ....
Ver 3.10
To set other memory switches, select the relevant screen using the [ ] (next
screen) or [
] (previous screen) touch switch, then make the setting.
To confirm the settings and quit the memory switch setting screen, press the
Quit touch switch. The settings made last will be set and the NT31/NT31C will
return to the MAINTENANCE MODE MENU screen.