Omron Programmable Terminals NT31 NT31C Manual de usuario Pagina 173

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 172
6-7SectionSetting Conditions for Communications with Host by Using Memory Switches
163
6-7-4 Setting the NT Link (1:N) Method (Standard/High-speed)
Set the communication conditions for the NT link (1:N) method at serial port A or
serial port B by following the operation from the System Menu shown below.
The communications speed determines whether the 1:N NT Link is standard or
high-speed.
Standard: Standard 1:N NT Link
High-speed: High-speed 1:N NT Link
Select Maintenance Mode.
Select Memory Switch.
Display the fourth memory switch screen by
pressing the [] (next screen) or [] (previous
screen) touch switch.
Press the touch switch corresponding to the
port at which the NT link (1:N) method (stan-
dard or high-speed) is to be set (Comm. A
Method or Comm. B Method) to display the
setting option NT Link (1:N).
The setting option changes each time the
touch switch is pressed.
In this example, serial port A is used.
Ver 3.10
Vista de pagina 172
1 2 ... 168 169 170 171 172 173 174 175 176 177 178 ... 295 296

Comentarios a estos manuales

Sin comentarios